Food production puts the highest demands on quality and hygiene

When it comes to food, the requirements can’t be strict enough. After all, in directly involves our health. Therefore, this sector has extremely high standards for the technology and material of all components involved.

Pumps from Wilo will convince you with their reliability and functionality

In every process stage, production parameters, such as temperature and impermeability, must be exactly complied with to guarantee critical quality and hygiene standards. Thus, pumps must constantly prove their functionality and reliability.


Vertical Sump Pump

Design

  • Vertical wet pit volute pump with
  • Dry motor
  • Stage: Single
  • Closed impeller
  • Oil lubricated bearing arrangement antifriction bearing
  • Mechanical seal/ gland packing

Application

  • Emergency oil pump
  • Dewatering

Special features / product benefits

Technical data

  • Qmax: 750 m3/hr
  • Hmax: 220 m
  • Temperature: up to 80°C
  • Delivery Size: DN 32 – DN 200
Sewage/Wastewater Pump (Drypit Non Clog)

Design

  • End suction top discharge
  • Mounting: Horizontal
  • Stage: Single
  • Casing with hand hole inspection cover mechanical seal/ gland packing large free passage up to 200 mm
  • Grease lubricated antifriction bearing

Application

  • Municipal raw sewage transfer
  • Sewage treatment plants
  • Effluent treatment plants
  • Dirty water in industry
  • Sugar mills

Special features / product benefits

  • Mounting: Vertical
  • Delivery flange orientation
  • change possible
  • Bush bearing

Technical data

  • Qmax: 8000 m3/hr
  • Hmax: 70 m
  • Temperature: up to 70°C
  • Delivery Size: DN 50 – DN 800
Standard Horizontal Split Case Pump

Design

  • Mounting: Inline horizontal
  • Stages : Single/ double, single/ double suction Impellers shaft with sleeves
  • Grease lubricated anti-friction bearing
  • Mechanical seal/ gland packing

Application

  • Water supply / general industry
  • Building service / fire fighting
  • Spray irrigation / district heating

Special features / product benefits

  • Mounting: Vertical

Technical data

  • Qmax: m3/hr max 3400
  • Hmax: 235 m
  • Temperature: up to 120°C; Higher on request
  • Delivery Size: DN 50 – DN 400
PISO

Design

  • Standards as per ISO 2858
  • End suction top discharge
  • Stage single
  • Back pullout design
  • Closed Impeller
  • Gland packing/Mechanical seal

Application

  • HVAC systems
  • Water transfer
  • Distribution systems
  • Fire fighting
  • Cooling tower

Special features / product benefits

Bearing Housing

  • Unique design for Grease & Oil Lubrication
  • Provisions for temperature gauge / vibration probe

Bearings

  • NR type replaced with standard type

Technical data

  • Qmax: 750 m3/hr
  • Hmax: 170 m
  • Temperature: -20ºC to 120ºC
  • Delivery Size: 32 – 200
Norm Pump as per EN733

Design

  • End suction top discharge
  • Mounting: Horizontal
  • Stage: Single
  • Back pullout design
  • Closed impeller
  • Mechanical seal/ gland packing
  • Grease lubricated antifriction bearings

Application

  • Building service
  • Sprinkler systems
  • Water supply
  • General industry

Special features / product benefits

Technical data

  • Qmax: 600 m3 /hr
  • Hmax: 150 m
  • Temperature: up to 1200C
  • Delivery Size: DN 32 – DN 150
MISO

Design

  • Standards as per ISO 2858
  • End suction top discharge
  • Stage single
  • Back pullout design
  • Closed Impeller
  • Gland packing/Mechanical seal

Application

  • HVAC systems
  • Water transfer
  • Distribution systems
  • Fire fighting
  • Cooling tower

Special features / product benefits

Bearing Housing

  • Unique design for Grease & Oil Lubrication
  • Provisions for temperature gauge / vibration probe

Bearings

  • NR type replaced with standard type

Technical data

  • Flow: upto 750 m3/hr
  • Head: upto 170 m
  • Temperature: -20ºC to 120ºC
  • Delivery Size: 32 – 200
Engineered Horizontal Split Case Pump (HSC)

Design

  • Mounting: Inline horizontal
  • Stages: One/ two/ three stage single/ double suction impellers
  • Grease/ Oil lubricated antifriction bearings
  • Mechanical seal/ gland packing

Application

  • Water supply/ general industry
  • Ports & docks/ fire fighting
  • Irrigation/ marine desalination

Special features / product benefits

  • Mounting: Centre line/ vertical
  • Drive connection: direct/ cardan shaft bush bearing
  • Staggered vane design for fan pump application
  • Special suction/ delivery orientation* instrumentation & controls

Technical data

  • Qmax: m3/hr max 18000
  • Hmax: 270 m
  • Temperature: up to 120°C; Higher on request
  • Delivery Size: DN 50 – DN 400
End Suction Pump Engineered/ Special

Design

  • End suction top discharge
  • Mounting: Horizontal
  • Stage: Single
  • Back pullout design
  • Closed impeller
  • Mechanical seal/ gland packing grease/oil lubricated antifriction bearings

Application

  • Water supply/ general industry
  • Paper & pulp/ building service
  • Fire fighting/ irrigation/ sprinkler system
  • Treated effluent

Special features / product benefits

  • Mounting: Centreline/ vertical
  • Delivery flange orientation change possible
  • Bush bearing

Technical data

  • Qmax: 3400 m3/hr
  • Hmax: 220 m
  • Temperature: up to 120°C
  • Delivery Size: DN 50 – DN 400